ELECTRICAL CONDUCTIVITY (EC)

Take a look at our offers of high quality EC testers from the Milwaukee brand. Milwaukee conductivity meters are some of the best alternatives on the market. We offer waterproof and electronic testers and controllers at affordable prices in Growshop Mania.
Filters
«1»

Milwaukee EC65/C66 meter

Milwaukee C65 / C66 is a waterproof EC tester, specially designed for hydroponics and agricultural markets, with automatic temperature compensation and manual calibration with 1 point.

 


The EC tester has a range of 0.00 to 10.00 mS / cm as well as an optional electrode option and is supplied in a battery pack, calibration solution (M10031) and a calibration screwdriver. The modular design allows easy replacement of the electrode and batteries.

 

 

Specifications:

 

  • range: from 00 to 10.00 mS / cm
  • resolution: 0.01 mS / cm
  • accuracy: ± 2%;
  • Calibration: automatic, single point
  • automatic temperature compensation with β = 2% / ° C
  • Operating conditions: -5 to 50 ° C / 32 to 122 ° F ;, humidity up to 100%
  • batteries: 3 x 1.5V (included)
  • Battery life: approx. 250 hours of continuous use
  • dimensions: 165 x 30 x 30 mm

 


CALIBRATION:

  • Frequent calibration is recommended for maximum measurement accuracy.
  • Immerse the tester electrode in a glass of tap water
  • Immerse the probe in a suitable calibration solution: 1413 mS / cm.
  • Open the top cover of the tester and, using the screwdriver included in the kit, turn until 1.41 appears on the display.
Price: €42.97
Quantity:

Milwaukee EC monitor MC310

Accurate, easy to use and reliable. 24/7 EC monitoring

The Milwaukee MC310 PRO Conductivity (EC) Monitor allows you to automatically measure EC levels and alerts you with an alarm when you are out of set point range.

The MC310 EC automatically monitors your EC levels. Simply set your EC parameters and let the Milwaukee EC Monitor do the rest.
It is often used in nutrient tanks, hydroponics and gardening.
The Milwaukee PRO EC monitor offers:
ACCURACY
The Milwaukee PRO EC monitor offers accuracy up to ±2% of full scale.
AUTOMATION
The monitor has a set point range of 1.0 to 5.0 mS/cm with alarms that activate when readings are above or below the set point.

Price: €141.18
Quantity:

Milwaukee EC60 meter

Pocket Size Waterproof Tester for EC / TDS / Temp.

 

Includes features such as replaceable probe , temperature measurement in °C or °F, automatic temperature compensation with adjustable ß, battery level indicator, stability indicator, auto-shutoff and auto- calibration all in a floating, waterproof housing.

 

Measurements are displayed at two levels on the LCD display: EU (20.00 Ms / cm) or TDS (10.00 PPT). It also displays the temperature from 0.0 to 60.0 °C (or 32.0 to 140.0 °F) on the secondary level at the same time.

 

 

INSTRUCTIONS FOR WORKING WITH THE TESTER:

  • Remove the cap and turn on the tester by pressing the ON/OFF button. All usable segments of the LCD screen will be visible for about a second or as long as you hold the button.
  • Immerse the probe in the solution you want to measure, select either EC or TDS mode with the SET/HOLD button.
  • Gently mix the solution with the probe in a circular motion and wait for the reading to stabilize. I.e. until the hourglass symbol on the LCD screen turns off.
  • The EC or TDS value is automatically temperature compensated and will be displayed on the main LCD, while T will be displayed on the secondary LCD.
  • To lock the display while in measurement mode, press and hold the SET/HOLD button. The message “HOLD” will be displayed on the secondary display and locked on the LCD screen. Press any button to return to normal mode.
  • To turn the tester off, press the ON/OFF button. The message “OFF” will appear on the secondary display. Release the button.
  • Before each measurement, make sure that the tester is calibrated (you can know this if the inscription “CAL” lights up on the display)
  • After each use of the tester, always turn it off, rinse its probe with water and store it with the cap closed.

 

 

SETTINGS:

  • This mode allows you to change the winterization units for temperature C/F, conversion factor (CONV) and temperature coefficient (BETA). To enter this mode, press and hold the ON/OFF button until “CAL” on the secondary display replaced by "TEMP" then:
  • To select C/F unit, press the SET/HOLD button, then press the ON/OFF button once to enter buffer settings or twice to return to normal mode.
  • To change the TDS value after you have set the temperature section, press ON/OFF once to display the current value (eg 0.50 CONV). Select the desired value by pressing the SET/HOLD button, then press ON/OFF twice to return to normal mode.
  • To change the temperature coefficient. After setting the TDS factor, press ON/OFF to display the current temperature coefficient value (eg 2.1 BETA). Press the SET/HOLD button to set the desired value, then press ON/OFF to to return to normal mode.

 

 

CALIBRATION:

  • For maximum measurement accuracy, frequent calibration is recommended.
  • From normal EC mode, press and hold the ON/OFF/CAL button until the “OFF” message on the display is replaced by the “CAL” message. Release the button.
  • Immerse the probe in a suitable calibration solution: 12.88 mS/cm.
  • After the value is read automatically, the LCD screen will display “OK” for about a second and the tester will return to normal, measuring mode.

 

 

There is no need to recalibrate the tester if you decide to change the measurement setting from EU to TDS.

 

When the calibration procedure is completed correctly, the inscription “CAL” lights up on the screen.

 

To reset to default settings and clear previous calibration, press the ON/OFF/CAL button after entering the calibration mode and before the calibration point is accepted. The secondary display will read “CLR” for about a second, the tester returns to its factory defaults settings and the inscription “CAL” turns off on the display automatically,

 

Price: €55.75
Quantity:

Milwaukee EC CD611 meter

Milwaukee's economical testers are easy-to-use and low cost instruments to measure quick and reliable pH, EC or TDS values.

 

 

Measuring electrical conductivity is the best way of checking the amount of salt or dissolved solids (TDS) in water. Milwaukee provides you with a range of pocket testers that will allow you to measure from very low to very high conductivity solutions. All EC/TDS testers compensate for the temperature variance automatically.

 

The CD611 is a Conductivity tester specifically designed for water analysis. The calibration procedure is very simple and fast. This tester has automatic temperature compensation, 100 µS/cm resolution and a range of 0 to 20000 µS/cm. CD611 is supplied complete with protective cap, calibration screwdriver, batteries and instructions.

 

Price: €37.85
Quantity:
Page 1 of 1
«1»

Bestsellers:

Facebook

 

Working hours - Sofia:

Mon - Fri: 10:00 a.m. - 7:00 p.m
Sat: 10:00 - 18:00

Sun: Day off

 

Working hours - Varna:

Mon - Fri: 09:00 - 18:00
Sat -
Sun : Holidays

 

Addresses

Sofia, Nikolay Liliev St., №10

 

 

Varna , Han Presiyan St., №1