BlueLab ph soil pen
-
Code:1310
-
Weight:0.300 Kgs
Features:
- Selectable units for °C and °F
- Fully waterproof
- LCD display with backlight
- Read hold function
- Storage cap
- Automatic shut-off function
Quick Buy
The Bluelab Soil pH Pen is an accurate way to measure soil pH and temperature directly in the root zone of your plants. If necessary, the soil pH pen can be used in nutrient solutions .
Simply poke a hole in the soil with the storage cap and insert the probe to get constant pH and temperature measurements.
Specifications:
- Measuring range: pH 0.0 - 14.0; Temperature 0 - 50°C, 32 - 122°F
- Resolution: pH: 0.1; Temperature: 1°C, 1°F
- Accuracy at 25 ° C / 77 ° F:
pH 0.1 ±; Temperature: ± 1 ° C ± 2 ° F
- Calibration: Two points (pH 7.0 and pH 4.0 or pH 10.0)
- Automatic temperature compensation: Yes
- Operating environment: 0-50°C, 32-122°F
- Power source: 1 x AAA alkaline batteries
- Certificates: CE; FCC; WEEE
How to use:
**Important : You must calibrate your pH pen before first use .
- Use the storage cap to make a hole in the soil. Place as deep as the roots of your plant.
- Carefully remove the storage cap by first unscrewing the cap and gently pulling to remove the probe. The cap contains KCl solution , so be careful not to spill the liquid. The formation of a salt crust around the probe is normal.
- Turn on the pen and insert the probe into the opening. Make sure the tip of the probe is in contact with the soil at the end of the hole. The display will stabilize and give you pH and temperature readings.
- Rinse after use to remove nutrient or dirt build-up and replace cap for storage
How to calibrate:
**Calibrate after each cleaning and at least once a month.
- Turn on the pH pen.
- Calibrate to pH 7 by placing the probe tip in a pH 7 solution . Wait for the reading to stabilize between pH 6.6 - pH 7.5 .
- Long press the Cal button until CAL is displayed. Release the button. The calibration sequence will begin flashing "0" on the display in sequence. Once “0000” stops flashing, the sequence is complete. Rinse the probe tip in fresh tap water.
- Repeat with pH 4 solution.
- A checkmark will confirm successful calibration.
Hydrate
** Keep the probe hydrated with Bluelab KCl solution. Without proper hydration, readings may be inaccurate and the probe may break.
1. Add enough KCl storage solution to submerge the tip of the probe in a plastic cup and allow to soak for 24 hours.
2. Make sure there are a few drops of KCl solution in the storage cap
The tester is guaranteed against defects for a period of 5 years from the date of purchase. During this period, the device can be returned to the seller with proof of purchase (receipt). If a defect is found, it will be repaired or replaced.
This warranty does NOT cover misuse of the device, accidental damage (abrasion, getting wet), repairs by unauthorized persons. 6 month warranty on the Ph probe.
Found a better price?
Delivery conditions
CONDITIONS FOR DELIVERY
- Door-to-door orders on the territory of Bulgaria are sent with Econt Express on the next day of the order.
- Delivery to other countries is estimated within 3-6 business days.
- If the item you ordered is not available, we will contact you to inform you about the delivery time and to confirm your order.
- The delivery price is indicative and is recalculated according to the rates of the courier company.
- All goods are packed in a way that prevents any damage. If you notice the packaging is damaged, once your package has arrived, inform the transporter!
- Goods are always packed in discreet packaging.
NOTE: The delivery companies may experience delays on Black Friday and Official Holidays due to an increase in shipping volume. Thank you for your patience and understanding.
Order items at a regular price with a total value of over BGN 100 and pick up with FREE DELIVERY to an Econt office.