monitor Milwaukee pH MC110
-
Code:1858
-
Weight:0.160 Kgs
Professional pH monitor for long-term use
The MC series devices are designed for continuous monitoring of pH, EC or TDS values, directly in the tank. Each unit has a user-selectable mode selection. The LED indicator is activated and starts flashing when the pH, EC or TDS level changes above or below (user-selected) the set value.
The pH monitor for constant monitoring of hydroponic or fertilizer solutions , aquariums and aquaponic systems, pools, etc. has a convenient function for visual indication when the pH of the solution passes a set (by the grower) value (up or down, selectable by button).
- Manual calibration at 2 fixed points - pH 4 and pH 7.
- Separately connectable sensor, compatible with pH monitors from other manufacturers.
- LED alarm
- Supplied with 12 VDC adapter, mounting kit and 20 ml pH 7.01 calibration solution
- Double, cross-shaped pH electrode with two meters of cable (BNC connector)
Quick Buy
The Milwaukee MC110 PRO pH Monitor (mid-range setpoint) offers laboratory accuracy with easy-to-see continuous verification of pH levels with alarms.
Features:
- Fast and easy-to-read results with large digital LCD display
- Accuracy ±0.2 pH with full pH range
- The pH alarm setpoint range from 3.5 to 7.5 is easily accessible on the front panel
- Alarm is activated when reading is above or below set point
- Easy manual calibration via front panel trimmers
- Comes with a complete installation kit including probe holders
- Gel-filled, dual-junction laboratory probe designed for easy maintenance
- 12 VDC power supply
- Small size 5.9 x 3.2 x 1.35”
- Lightweight monitor weighing approximately 5.6 oz.
Milwaukee PRO pH Probe Care
pH meters usually start to malfunction due to problems with the probe. The two parts of the pH probe that cause problems are the glass sensor bulb and the reference junction.
You can extend the life of your pH electrode in the following ways.
Storage
The pH probe must be kept hydrated. Long periods of storage in a dry place will damage the sensitivity of the probe. Drying out the probe can also cause the connection hole to become clogged.
Store the pH probe in storage solution. Use tap water only briefly if storage solution is not immediately available, and NEVER store in distilled (DI) or reverse osmosis (RO) water. This will damage the sensitivity of the probe.
The best way to store the probe is with the probe cap filled with storage solution and the cap tightened to prevent leakage. It is also recommended that the electrode be stored upright to further reduce the potential for leakage.
Cleaning
Sample residue can affect the sensitivity of the sensor bulb and block the connection. This is especially true if the sample contains a lot of organic material. We recommend regularly soaking the probe in cleaning solution for about 20 minutes.
Calibration
pH sensor tips lose sensitivity over time, so make sure to calibrate regularly to keep your pH meter PRO accurate. Also, calibrate after cleaning or long periods of storage.
The tester is guaranteed against defects for a period of 12 months for the device and 6 months for the sensor from the date of purchase. During this period, the device can be returned to the seller with proof of purchase (receipt). If a defect is found, it will be repaired or replaced.
This warranty does NOT cover misuse of the device, accidental damage (dropping, getting wet), or repairs by unauthorized persons.
| File | Info |
|---|---|
ISTMC110_07_20
|
[PDF, 330.18 KB] |
Found a better price?
Delivery conditions
FREE SHIPPING CONDITIONS
- The total value of the goods ordered online must be over 50.00 €.
- The order must NOT contain discounted or promotional items.
- The order must be delivered to an Econt office in Bulgaria.
- If the customer has ordered a product whose availability has not been confirmed, in order to benefit from free shipping, they must replace it with another one to reach the required threshold of the total bill.
- The conditions for free delivery are valid on the territory of the Republic of Bulgaria.
- The store reserves the right to make changes to the free shipping conditions.
STANDARD DELIVERY TERMS
- The delivery time for available products is 24 hours.
- Orders placed by 5:30 PM are fulfilled on the same day and are sent by courier to any point in the country.
- Orders placed after 5:30 PM are shipped the next business day.
- If the item you ordered is not available, we will contact you to inform you of the delivery time and to confirm your order.
- Cash on delivery deliveries - you pay the value of the products to the courier/at the courier's office at the time of delivery.
- The delivery price is approximate and is recalculated according to Econt Express rates.
CLICK & COLLECT - Order online, pick up in store - in three easy steps
- Place an order for the items you want and select the delivery method "Pick up from store - Varna" or "Pick up from store - Sofia".
- You will receive confirmation from our consultant by phone.
- Come to the store of your choice to receive your order without additional delivery fees.
Order items at a regular price with a total value of over BGN 100 and pick up with FREE DELIVERY to an Econt office.


ISTMC110_07_20