Bluelab ph probe care
-
Code:1642
-
Weight:0.400 Kgs
pH measuring equipment should be regularly cleaned and calibrated so that the user can be sure that the readings are accurate. The pH testers are calibrated using pH7.0 (buffer) and pH4.0 (bias) solutions before each measurement. Calibration solutions should be stored in cool places away from direct sunlight and heat.
The set contains:
- 2 sachets x 20ml with calibration solution pH 7.0
- 2 sachets x 20ml with calibration solution pH 4.0
- 2 sachets x 20ml with KCl storage solution
- 3 plastic cups
- A tube of pH probe cleaning solution
- Brush (pH probe cleaning tool)
Quick Buy
When to calibrate your pH pen or probe:
- Before first use
- If the calibration reminder has disappeared from the LCD screen (30 days after the first calibration)
- If the pH reading is different than expected
- After cleansing and hydration
- After changing the batteries
To calibrate your pH pen or probe, follow the steps below:
1. Make sure your pen or probe is clean and hydrated.
2. Turn on the pH pen or probe. Press the power/hold button.
3. First calibrate to pH 7. Place the probe tip in fresh Bluelab pH 7.0 calibration solution. Wait for the reading to stabilize between pH 6.6 - pH 7.5. Long press the Cal button on the pen or meter until "CAL" is displayed. Release button. A calibration sequence will begin with the display flashing "0" continuously. Once "0000" stops flashing, the sequence is complete and "pH7" is displayed.
4. Rinse. Rinse the tip of the pen or probe thoroughly in clean tap water and shake off any excess.
5. Calibrate to pH 4. Place the probe tip in fresh Bluelab pH 4.0 calibration solution. Wait for the reading to stabilize between 3.6 pH - 4.5 pH . Long press the Cal button until “CAL” is displayed. Release button. A calibration sequence will begin with the display flashing "0" continuously. Once “0000” stops flashing, the sequence is complete and “pH4” is displayed.
6. Confirm the calibration. A calibration confirmation will appear at the bottom of the pen or probe screen to indicate a successful calibration. It will disappear after 30 days to indicate that a new calibration is required.
Found a better price?
Delivery conditions
CONDITIONS FOR DELIVERY
- Door-to-door orders on the territory of Bulgaria are sent with Econt Express on the next day of the order.
- Delivery to other countries is estimated within 3-6 business days.
- If the item you ordered is not available, we will contact you to inform you about the delivery time and to confirm your order.
- The delivery price is indicative and is recalculated according to the rates of the courier company.
- All goods are packed in a way that prevents any damage. If you notice the packaging is damaged, once your package has arrived, inform the transporter!
- Goods are always packed in discreet packaging.
NOTE: The delivery companies may experience delays on Black Friday and Official Holidays due to an increase in shipping volume. Thank you for your patience and understanding.
Order items at a regular price with a total value of over BGN 100 and pick up with FREE DELIVERY to an Econt office.