Currency
EUR
  • BGN
  • EUR
  • RON
Menu
Profile
Language

Category

Home Tags

waterproof digital ec tester

«1»

Products

Milwaukee EC65/C66 meter

Milwaukee C65 / C66 is a waterproof EC tester, specially designed for hydroponics and agricultural markets, with automatic temperature compensation and manual calibration with 1 point.

 


The EC tester has a range of 0.00 to 10.00 mS / cm as well as an optional electrode option and is supplied in a battery pack, calibration solution (M10031) and a calibration screwdriver. The modular design allows easy replacement of the electrode and batteries.

 

 

Specifications:

 

  • range: from 00 to 10.00 mS / cm
  • resolution: 0.01 mS / cm
  • accuracy: ± 2%;
  • Calibration: automatic, single point
  • automatic temperature compensation with β = 2% / ° C
  • Operating conditions: -5 to 50 ° C / 32 to 122 ° F ;, humidity up to 100%
  • batteries: 3 x 1.5V (included)
  • Battery life: approx. 250 hours of continuous use
  • dimensions: 165 x 30 x 30 mm

 


CALIBRATION:

  • Frequent calibration is recommended for maximum measurement accuracy.
  • Immerse the tester electrode in a glass of tap water
  • Immerse the probe in a suitable calibration solution: 1413 mS / cm.
  • Open the top cover of the tester and, using the screwdriver included in the kit, turn until 1.41 appears on the display.
Price: €42.97
Quantity:

EC CF PPM NUTRIENT METER SWRS-100A

It is essential when growing hydroponically that you know the strength of the nutrient solution before giving it to your plants.

If the conductivity reading is too low, your plants are not getting enough nutrients. If the conductivity reading is too high, plants can become dehydrated.

 

- Range : 4-44CF; 0.4-4.4EC; 280-3080ppm
- Resolution : 0.1 EC (1 CF)
- Accuracy : +/- 4% of reported

 

Price: €51.15
Quantity:

Milwaukee EC60 meter

Pocket Size Waterproof Tester for EC / TDS / Temp.

 

Includes features such as replaceable probe , temperature measurement in °C or °F, automatic temperature compensation with adjustable ß, battery level indicator, stability indicator, auto-shutoff and auto- calibration all in a floating, waterproof housing.

 

Measurements are displayed at two levels on the LCD display: EU (20.00 Ms / cm) or TDS (10.00 PPT). It also displays the temperature from 0.0 to 60.0 °C (or 32.0 to 140.0 °F) on the secondary level at the same time.

 

 

INSTRUCTIONS FOR WORKING WITH THE TESTER:

  • Remove the cap and turn on the tester by pressing the ON/OFF button. All usable segments of the LCD screen will be visible for about a second or as long as you hold the button.
  • Immerse the probe in the solution you want to measure, select either EC or TDS mode with the SET/HOLD button.
  • Gently mix the solution with the probe in a circular motion and wait for the reading to stabilize. I.e. until the hourglass symbol on the LCD screen turns off.
  • The EC or TDS value is automatically temperature compensated and will be displayed on the main LCD, while T will be displayed on the secondary LCD.
  • To lock the display while in measurement mode, press and hold the SET/HOLD button. The message “HOLD” will be displayed on the secondary display and locked on the LCD screen. Press any button to return to normal mode.
  • To turn the tester off, press the ON/OFF button. The message “OFF” will appear on the secondary display. Release the button.
  • Before each measurement, make sure that the tester is calibrated (you can know this if the inscription “CAL” lights up on the display)
  • After each use of the tester, always turn it off, rinse its probe with water and store it with the cap closed.

 

 

SETTINGS:

  • This mode allows you to change the winterization units for temperature C/F, conversion factor (CONV) and temperature coefficient (BETA). To enter this mode, press and hold the ON/OFF button until “CAL” on the secondary display replaced by "TEMP" then:
  • To select C/F unit, press the SET/HOLD button, then press the ON/OFF button once to enter buffer settings or twice to return to normal mode.
  • To change the TDS value after you have set the temperature section, press ON/OFF once to display the current value (eg 0.50 CONV). Select the desired value by pressing the SET/HOLD button, then press ON/OFF twice to return to normal mode.
  • To change the temperature coefficient. After setting the TDS factor, press ON/OFF to display the current temperature coefficient value (eg 2.1 BETA). Press the SET/HOLD button to set the desired value, then press ON/OFF to to return to normal mode.

 

 

CALIBRATION:

  • For maximum measurement accuracy, frequent calibration is recommended.
  • From normal EC mode, press and hold the ON/OFF/CAL button until the “OFF” message on the display is replaced by the “CAL” message. Release the button.
  • Immerse the probe in a suitable calibration solution: 12.88 mS/cm.
  • After the value is read automatically, the LCD screen will display “OK” for about a second and the tester will return to normal, measuring mode.

 

 

There is no need to recalibrate the tester if you decide to change the measurement setting from EU to TDS.

 

When the calibration procedure is completed correctly, the inscription “CAL” lights up on the screen.

 

To reset to default settings and clear previous calibration, press the ON/OFF/CAL button after entering the calibration mode and before the calibration point is accepted. The secondary display will read “CLR” for about a second, the tester returns to its factory defaults settings and the inscription “CAL” turns off on the display automatically,

 

Price: €55.75
Quantity:

ADWA AD32 Waterproof EC tester

​ADWA AD32 - Waterproof EC Tester

  • LCD display
  • Automatic temperature compensation
  • Automatic shutdown after 8 minutes
  • Automatic one point calibration
  • Including. 4 x 1.5V batteries and protective cover
  • Battery life: ± 100 hours
  • Waterproof
  • Dimensions: 175.5 x 39 x 23 mm
  • Package dimensions: 230 x 60 x 68 mm
  • Weight: 100 grams
  • Range: 0:00 to 20:00 MS / cm, 0.00 - 10:00 PPT, 0.0 ° C - 60.0 ° C
  • Resolution: + / - 2% FS (EC / TDS), + / -0.5 ° C
  • Accuracy: 0.01 MS / PPT and 0.1 °C
 
 
EC calibration. For greater accuracy, frequent calibration of the tester is recommended (at least once every 2 weeks).
 
 
 
- Suitable calibration solutions can be found here .
 
-10%
Price: €46.03
List Price: €51.15
discounts info
Discounts info
Price: €46.03
List Price: €51.15
Discount: €5.12 (10.00%)
Quantity:

EC-Meter Truncheon

The Bluelab Truncheon Meter is a robust and reliable everyday tool for measuring the concentration of nutrients in solution. With Truncheon, you'll ensure your plants get the nutrients they need for superior plant health.

Truncheon is factory calibrated with no moving parts or switches. Simply dip the probe into your feed tank and take the reading shown on the LED display.

Characteristics:

  • Blue light display
  • No calibration required
  • EC, CF and ppm 500 and ppm 700 scales
  • Fully waterproof
  • Automatic on/off function

How to take your first measurement:

  1. Remove the meter from the packaging.
  2. Dip the probe head into your solution.
  3. Wait about 10 seconds for the thermistor to reach the temperature of the solution.
  4. Read the measurement indicated by the flashing LEDs. If the flashing lights alternate between two numbers, the measurement is the value between those two numbers. For example, if the lights alternate from 0.8EC and 1.0EC, the reading is 0.9EC.
  5. Truncheon will turn off after about 10 seconds. If additional measurements are to be taken, remove the stick from the solution, wait a few seconds and reinsert it. It will turn on again.
  6. We recommend that the probe be cleaned and accuracy checked in Bluelab 2.77 EC Solution once a month.



Note: For low or high temperatures, it may take 1-2 minutes for the probe to reach solution temperature. Try placing the probe in an area where there is strong movement of the solution, or stir the solution with the probe.

Tip: In addition to being used to measure nutrient levels, the Truncheon Meter can also be used to stir nutrients into your solution.

 

-13%
Price: €113.47
List Price: €130.43
discounts info
Discounts info
Price: €113.47
List Price: €130.43
Discount: €16.96 (13.00%)
Quantity:
Page 1 of 1
«1»

Bestsellers:

Facebook

 

Working hours - Sofia:

Mon - Fri: 10:00 a.m. - 7:00 p.m
Sat: 10:00 - 18:00

Sun: Day off

 

Working hours - Varna:

Mon - Fri: 09:00 - 18:00
Sat -
Sun : Holidays

 

Addresses

Sofia, Nikolay Liliev St., №10

 

 

Varna , Han Presiyan St., №1